Back to the list
Congress: ECR25
Poster Number: C-11163
Type: Poster: EPOS Radiologist (scientific)
Authorblock: A. Piacentini, G. Kasprian, P. Sorgo, G. Bodner, J. Streicher, V. Moser, S. A. Jengojan; Vienna/AT
Disclosures:
Alessio Piacentini: Nothing to disclose
Gregor Kasprian: Nothing to disclose
Philipp Sorgo: Nothing to disclose
Gerd Bodner: Nothing to disclose
Johannes Streicher: Nothing to disclose
Veith Moser: Nothing to disclose
Suren Armeni Jengojan: Nothing to disclose
Keywords: Interventional non-vascular, Musculoskeletal soft tissue, Musculoskeletal system, Percutaneous, Ultrasound, Puncture, Dissection
Methods and materials

Fifteen ultrasound-guided carpal tunnel thread releases were performed on the wrists of soft-embalmed anatomical specimens, which were dissected immediately after the intervention. All study-related procedures were conducted at the Department of Anatomy and Developmental Biology of Karl Landsteiner University for Health Sciences in St. Pölten, Austria, between June and November 2021. The procedures were performed by two musculoskeletal radiologists with 25 and 8 years of experience respectively in interventional radiology. Ultrasound visibility, completeness of transection and damage to surrounding structures were evaluated on a score from one to three.